Get Quote
HFC-227ea · FM-200 CLEAN AGENT

PAVLN HFC-227ea Fire Suppression Systems

Fast, residue-free fire protection for critical equipment and facilities. PAVLN offers piped, externally pressurized, cabinet-type, and ceiling-mounted HFC-227ea systems, supported by customized engineering and international project support.

  • Fast Discharge · No Residue
  • Electrically Non-Conductive · Ideal for Sensitive Equipment
  • Engineering Support for NFPA 2001 & ISO 14520 Requirements
Discuss Your Project

Request a Custom Quote & Engineering Support

Tell us what you need — our team will review your inquiry and respond within 24 hours.

Please enter your name.
Please enter your country or region.
Please enter a valid phone or WhatsApp number.
Please enter a valid email address.
Please briefly describe your requirements or inquiry.
Thank you! Your request has been received — our engineer will reply within 24 hours.
< 10sDischarge target for applicable total-flooding designs
No ResidueClean agent protection for sensitive equipment
4+ TypesFlexible fire suppression configurations
24hEngineering response, worldwide technical support

HFC-227ea Fire Suppression System Portfolio

Explore piped, externally pressurized, cabinet-type, and ceiling-mounted HFC-227ea systems, with flexible configurations and engineering support tailored to your project requirements.

Piped HFC-227ea (Heptafluoropropane) Fire Suppression System (4.2 MPa)

Piped HFC-227ea Fire Suppression System (4.2 MPa)

A reliable stored-pressure system for protecting enclosed spaces such as server rooms, electrical rooms and industrial facilities. Supports single-zone or multi-zone protection through engineered piping networks.

Storage Pressure4.2 MPa (20°C)
Extinguishing AgentHFC-227ea (FM-200)
Agent Discharge Time≤ 10 s
Operating Temperature0°C ~ +50°C
Get a System Quote
Piped HFC-227ea Fire Suppression System - Externally Pressurized Type (4.2 MPa)

Piped HFC-227ea System – Externally Pressurized Type (4.2 MPa)

Uses a separate high-pressure nitrogen supply to drive the extinguishing agent through the piping network. Designed for projects requiring flexible cylinder placement and extended discharge distances, subject to hydraulic calculations.

PressurizationExternal Nitrogen Supply
Nitrogen Charging Pressure13.5 MPa (20°C)
Agent Discharge Time≤10 s
Operating Temperature0°C ~ +50°C
Get a System Quote
Piped HFC-227ea (Heptafluoropropane) Fire Suppression System (5.6 MPa)

Piped HFC-227ea Fire Suppression System (5.6 MPa)

A higher-pressure stored-pressure system offering additional flexibility for engineered piping layouts. Suitable for projects with demanding distribution requirements, with pipe sizing and discharge performance verified through hydraulic calculations.

Storage Pressure5.6 MPa (20°C)
Extinguishing AgentHFC-227ea (FM-200)
Agent Discharge Time≤10 s
Operating Temperature0°C ~ +50°C
Get a System Quote
Piped HFC-227ea Fire Suppression System - Externally Pressurized Type (5.6 MPa)

Piped HFC-227ea System – Externally Pressurized Type (5.6 MPa)

An externally pressurized system using a separate nitrogen supply for agent discharge. Suitable for complex piping layouts, remote cylinder placement, and multi-zone protection, subject to project-specific hydraulic calculations.

Agent Storage Pressure0.39 MPa (20°C)
Nitrogen Charging Pressure13.5 MPa (20°C)
Agent Discharge Time≤10 s
Operating Temperature0°C ~ +50°C
Get a System Quote
Cabinet-Type HFC-227ea (Heptafluoropropane) Fire Suppression System

Cabinet-Type HFC-227ea Fire Suppression System

A compact, self-contained clean agent system with an integrated cylinder, release assembly, and cabinet-mounted discharge nozzle. Ideal for server rooms, electrical rooms, and archives where a dedicated cylinder room or piping network is not practical.

Storage Pressure2.5 MPa (20°C)
Maximum Operating Pressure4.2 MPa (50°C)
Agent Discharge Time≤10 s
Operating Temperature0°C ~ +50°C
Get a System Quote
Electrically Actuated Ceiling-Mounted HFC-227ea Suppression Unit

Ceiling-Mounted HFC-227ea Suppression Unit

A compact, self-contained suppression unit designed for ceiling installation in small, enclosed spaces. Available in electrically actuated and thermally actuated configurations, providing flexible protection without external discharge piping.

Storage Pressure1.6 MPa (20°C)
Actuation OptionsElectric / thermal bulb
Agent Discharge Time≤10 s
Operating Temperature0°C ~ +50°C
Get a System Quote

HFC-227ea Fire Suppression Solutions by Application

Explore HFC-227ea system options for different applications, with flexible configurations and engineering support tailored to your project's fire risks and requirements.

Data Centers & Server Rooms

Key engineering advantage

Fast, residue-free fire suppression helps protect sensitive IT equipment and critical server infrastructure without water-based discharge.

Discuss Your Project

Telecom & Base Stations

Key engineering advantage

Compact clean agent solutions for enclosed telecom equipment rooms and remote facilities, with flexible installation and actuation options.

Typical System Options:
Ceiling-Mounted HFC-227ea →
Discuss Your Project

Power Substations & Control Rooms

Key engineering advantage

Electrically non-conductive fire suppression for enclosed switchgear, control and relay rooms, with single-zone or multi-zone system configurations.

Discuss Your Project

UPS & Electrical Equipment Rooms

Key engineering advantage

Residue-free protection for UPS equipment and electrical rooms. Battery-specific hazards are evaluated separately to determine appropriate fire protection measures.

Discuss Your Project

Archives & Museums

Key engineering advantage

Clean agent protection helps safeguard historical documents, valuable collections and sensitive artifacts without water damage or extinguishing agent residue.

Discuss Your Project

Enclosed Flammable-Liquid Process Areas

Key engineering advantage

Engineered fire suppression for suitable enclosed Class B hazards, with design concentrations and system configurations based on specific fuels and fire risks.

Typical System Options:
Piped HFC-227ea Systems →
Discuss Your Project

Industrial Control & Automation Rooms

Key engineering advantage

Clean agent protection for PLC cabinets, automation control systems and industrial electrical rooms, helping minimize extinguishing agent residue around sensitive equipment.

Discuss Your Project

Laboratories & Testing Facilities

Key engineering advantage

Flexible clean agent solutions for suitable enclosed laboratories, testing rooms and sensitive instruments, with system design tailored to the specific fire hazards.

Discuss Your Project

Trusted for Critical Fire Protection Projects Worldwide

With nearly 30 years of fire protection experience, PAVLN delivers engineered fire suppression solutions across power, telecom, data centers and industrial facilities. Explore selected project references worldwide.

Utility-scale solar power plant protected by PAVLN systems

Utility-Scale Solar Power Plant

Hydropower station protected by PAVLN systems

Hydropower Station

Industrial plant protected by PAVLN systems

Industrial Manufacturing Plant

Power transmission project protected by PAVLN systems

Power Transmission Project

Power grid control center protected by PAVLN

Power Grid Control Center

National grid company facilities protected by PAVLN

National Grid Company Facilities

Substation and switchgear rooms protected by PAVLN

Substation & Switchgear Rooms

Hydropower complex control rooms protected by PAVLN

Hydropower Complex Control Rooms

International Fire Protection Standards & Engineering Support

PAVLN provides customized fire suppression solutions based on international standards, with engineering support, technical documentation and certification options tailored to project-specific requirements..

NFPA 2001

Clean agent fire suppression system design, agent quantity calculations and hydraulic analysis based on applicable NFPA 2001 requirements.

UL Listed Options

UL Listed component options available for projects with specific certification requirements, subject to system configuration and compatibility.

FM Approved Options

FM Approved component options available for projects requiring FM approval, subject to applicable certification scope and system configuration.

ISO 14520 / EN 15004

Customized system engineering and technical documentation based on applicable ISO 14520 and EN 15004 requirements.

Why EPC Contractors Choose PAVLN

From system engineering and manufacturing to technical documentation and international project support, PAVLN delivers customized fire suppression solutions tailored to your project requirements.

Nearly 30 Years of Fire Protection Experience

With nearly 30 years of industry experience, PAVLN provides fire suppression equipment and solutions for power, data centers, telecom and industrial applications worldwide.

About PAVLN

Manufacturing & Engineering Expertise

Combining manufacturing capabilities with engineering expertise, PAVLN supports system configuration, technical consultation and customized fire suppression solutions for diverse project requirements.

Explore Our Capabilities

International Standards & Compliance Support

Engineering support based on applicable NFPA 2001, ISO 14520 and EN 15004 requirements, with certification options evaluated according to project specifications.

Discuss Your Requirements

Customized System Design & Sizing

From system selection and agent calculations to pipe routing and technical drawings, our engineering team provides tailored support based on your project requirements.

Request Engineering Support

Global Delivery & Export Support

Reliable manufacturing and international shipping coordination, with export packing, documentation and delivery arrangements tailored to project requirements.

Ask About Lead Times

International Project Experience

Experience supporting fire protection projects across power, telecom, data centers and industrial facilities, with solutions adapted to different regional and technical requirements.

View Project References

OEM / ODM & Distributor Support

Flexible branding, product configurations and cooperation options for distributors, fire protection contractors and international project partners.

Explore Partnership Options

Comprehensive Fire Protection Portfolio

From clean agent and water mist systems to foam suppression and fire protection products, PAVLN offers a broad portfolio for diverse project applications.

Explore All Products

HFC-227ea (FM200) System FAQs

Find answers to common questions about system selection, engineering design, certification options and international project support.

1

Can you help design and size an HFC-227ea (FM200) fire suppression system for my project?

Yes. Share your application, approximate room dimensions or protected volume, fire hazards, and any available drawings or project specifications. Our engineering team can recommend suitable system configurations and provide preliminary sizing guidance. Detailed system design, hydraulic calculations, equipment selection and quotations can be prepared based on confirmed project requirements and applicable standards, such as NFPA 2001.
2

How far can the HFC-227ea cylinder bank be installed from the protected area?

The allowable distance depends on the system configuration, piping layout and hydraulic calculations. For projects requiring longer pipe runs, externally pressurized HFC-227ea systems may be considered. Our engineers evaluate pipe lengths, pressure losses and discharge performance to determine a suitable solution in accordance with applicable design standards.
3

Do you supply fire detection, control panels, and release circuits?

Yes. PAVLN provides integrated fire suppression solutions with optional smoke and heat detectors, fire suppression control panels, manual release stations, abort switches, pressure switches, and audible/visual alarms. System configurations, release circuits, and cause-and-effect logic can be tailored to project requirements and applicable fire safety standards.
4

Can FM200 (HFC-227ea) be used in normally occupied areas?

Yes. HFC-227ea systems can be designed for normally occupied spaces, including data centers and control rooms, provided that agent concentrations and exposure conditions meet applicable safety requirements. PAVLN designs systems in accordance with NFPA 2001, considering NOAEL/LOAEL limits, pre-discharge alarms, evacuation measures, and room pressure relief where required.
5

What certifications and technical documents can PAVLN provide?

PAVLN supports project-specific certification requirements, including UL/FM-certified components and configurations where required. Depending on the system and project specifications, we can provide applicable product certificates, test reports, quality documentation, and NFPA 2001-based design calculations. Certification availability and documentation scope are confirmed during project review.
6

What is the typical lead time and shipping arrangement?

Lead times for standard configurations are confirmed based on order details and production schedules. PAVLN supports export packing, shipping documentation, and international logistics coordination, with transportation options arranged according to shipment requirements.

Planning an HFC-227ea Fire Suppression Project?

Whether you need product information, system selection, engineering support, or a quotation, tell us about your requirements. Our team will review your inquiry and respond within 24 hours. pavln@pavln.com

  • Customized system selection & sizing support
  • Engineering consultation & technical documentation
  • International project support & NFPA 2001-based design

Request a Custom Quote & Engineering Support

Please enter your name.
Please enter your country or region.
Please enter a valid phone or WhatsApp number.
Please enter a valid email address.
Please briefly describe your requirements or inquiry.

Your information is used only to prepare your quotation. We never share project data with third parties.

Thank you! Your request has been received — our engineer will reply within 24 hours.

Home

Products

Projects

About Us

Contact Us